Commit Graph

8945 Commits

Author SHA1 Message Date
Tor Harald Sandve
4150ec5f67
Merge pull request #3756 from osae/letRelperms
Support for LET-based saturation functions.
2022-05-03 13:39:32 +02:00
Kai Bao
57d8f1aa24 update primary variables in prepareTimeStep
it should not change running results.
2022-05-02 13:47:16 +02:00
Tor Harald Sandve
74d8db36c5
Merge pull request #3859 from totto82/default_strict
use a relaxed (but not too relaxed) well tolerance when iter>6
2022-04-29 15:53:53 +02:00
Kai Bao
7145ec32ee renaming function updateWellState
to updatePrimaryVariablesNewton

this should be a fallout during the well code refactoring
2022-04-29 12:55:54 +02:00
Arne Morten Kvarving
7edca13df6 fixed: add missing config.h include 2022-04-28 11:38:02 +02:00
Markus Blatt
51d8c9536e Spelling fix geomtry -> geometry.
Actually one should rename the function used from opm-common, too.
But that is for later...
2022-04-27 20:52:30 +02:00
Markus Blatt
c66fb8a93d Added support for water-only and water-only + thermal to flow.
Also run the onephase tests with flow now.
2022-04-26 17:07:09 +02:00
Tor Harald Sandve
52fca6c91d use a relaxed (but not too relaxed) well tolerance when iter>6
also shut unsolvable wells during iterations as default

Note however that getWellConvergence return false if a well is unsolvable
i.e. it will cut the timestep and redo the iteration if the well is unsolvable
and only shut it completly if the time step is below the
MinTimeStepBeforeShuttingProblematicWellsInDays (default 0.01 days)
2022-04-26 10:55:22 +02:00
Tor Harald Sandve
4b5a53eaeb
Merge pull request #3887 from totto82/init_alt_eps
use alternative init for wells with all rates less than eps
2022-04-26 10:46:19 +02:00
Tor Harald Sandve
bd145913e8 use alternative init for wells with all rates less than eps 2022-04-26 09:32:18 +02:00
Atgeirr Flø Rasmussen
75ccd88f4f
Merge pull request #3888 from totto82/stop_tgr2
fix trivial group target
2022-04-26 08:34:06 +02:00
Atgeirr Flø Rasmussen
374b25639e
Merge pull request #3872 from totto82/fix_stop_inoperable
Fix STOP in combination with inoperable/unsolvable
2022-04-25 10:31:02 +02:00
Tor Harald Sandve
d00a2e2341 fix trivial group target 2022-04-25 08:10:19 +02:00
Markus Blatt
d58e11d591
Merge pull request #3875 from OPMUSER/Radial-Spider-Grid-Update-Backport-Candidate
Radial and Spider Grid Keywords Not Supported
2022-04-22 14:24:54 +02:00
Tor Harald Sandve
92175cf094 Fix STOP in combination with inoperable/unsolvable 2022-04-22 09:15:09 +02:00
Tor Harald Sandve
c8bef3bcd5 only check if wells has negative potentials if check_well_operabilty=true(default) 2022-04-22 08:19:33 +02:00
Tor Harald Sandve
969dff4ede
Merge pull request #3864 from totto82/regMSW
regularize MSW equation when iter > strict_inner_iter
2022-04-21 09:15:15 +02:00
Tor Harald Sandve
03c1884533
Merge pull request #3873 from totto82/aprox_thp
tighten approximated solution bhpFromThpLimit from 3 to 0.1 bar
2022-04-21 08:56:57 +02:00
Tor Harald Sandve
fd6cf1ccbd regularize MSW equation when iter > strict_inner_iter 2022-04-21 08:44:50 +02:00
Håkon Hægland
9d04895ddb Fix assertion error for 2p oil water
VFP calculations for two phase gas lift does not work unless the
rates are adpated to include a zero gas rate.
2022-04-20 21:47:15 +02:00
Håkon Hægland
11907495c1 Well testing of gas lift wells
Assign a maximum ALQ value to each GLIFT producer when doing well testing
in beginTimeStep(). This allows the well to be considered open. Then,
later in the timestep, when assemble() is called, the full gas lift
optimization procedure can adjust the ALQ to its correct value.

It is also observed that in some cases when gas lift is switched off by
setting ALQ to zero, and later in the schedule is switched back on again,
it might not be possible to determine bhp from thp for low small ALQ values.
Instead of aborting the gas lift optimization, we should try increasing
ALQ until we get convergence or until the maximum ALQ for the well is
reached.
2022-04-20 10:51:34 +02:00
OPMUSER
89461ed058 Radial and Spider Grid Keywords Not Supported
Add the DR, DTHETA and OUTRAD keywords as unsupported keywords with messages to enable the user to debug the input deck.

Back port candidate for release.
2022-04-20 14:19:56 +08:00
Tor Harald Sandve
a1d11540a6 tighten approximated solution bhpFromThpLimit from 3 to 0.1 bar 2022-04-19 14:21:20 +02:00
Tor Harald Sandve
edf8786a58 avoid throw for nan residuals instead return well as unconverged 2022-04-11 09:52:25 +02:00
Markus Blatt
ff410d268a
Merge pull request #3863 from totto82/unsolvable_fix
fix to --shut-unsolvable-wells=true option
2022-04-11 07:33:46 +02:00
Tor Harald Sandve
6f29bf715c
Merge pull request #3778 from GitPaean/always_inner
[testing] always using inner iterations for testing purpose.
2022-04-08 15:44:33 +02:00
Ove Sævareid
81249bccc4 Support for LET-based saturation functions. 2022-04-08 12:01:54 +02:00
Tor Harald Sandve
e501a84958 support item 4 wvfpexp 2022-04-08 08:43:13 +02:00
Tor Harald Sandve
0c9bb3990e
Merge pull request #3830 from plgbrts/vapwat
Adding explicit input specification of water-gas ratio (RVW) and RVW output plus simulator gas-water system with salt precipitation and water evaporation for
2022-04-07 09:03:26 +02:00
Markus Blatt
282951dc44
Merge pull request #3848 from blattms/binary-package-version-no-buildtime
Use empty string for buildtime if BUILD_TIMESTAMP is not set.
2022-04-05 14:54:58 +02:00
Tor Harald Sandve
e2e0ec9dd9 fix to --shut-unsolvable-wells=true option 2022-04-05 14:42:27 +02:00
Tor Harald Sandve
fba9046201 Some more clean-up based on review 2022-04-04 11:37:31 +02:00
Tor Harald Sandve
69ffed06de Address comments from review
1) Add debug messages
2) Fix bug of missing else in the code
2022-04-04 08:24:32 +02:00
Tor Harald Sandve
5b53fcd8a6 guard against d = 0 2022-04-04 08:24:32 +02:00
Tor Harald Sandve
2e91d2f353 Do not throw when d = 0 instead continue with rs/rv = 0 2022-04-04 08:24:32 +02:00
Atgeirr Flø Rasmussen
245a87e296
Merge pull request #3851 from totto82/doublecheckecon
Avoid premature closing of wells due to econ limits
2022-04-01 10:01:47 +02:00
Kai Bao
aa633ff98f reconstructing the if structure for has_energy
in StandardWell<TypeTag>::
    calculateSinglePerf()
2022-03-31 22:38:55 +02:00
Tor Harald Sandve
8909b259d0 don't shut wells due to ratio when rate is negative 2022-03-28 10:50:15 +02:00
Tor Harald Sandve
71acf4e056 Double check econ potential limits
Sometimes the potentials are inaccurate as a safty measure we
also check that the rates are violated.
The rates are supposed to be less or equal to the potentials.
2022-03-28 10:50:15 +02:00
Bård Skaflestad
dfdfbbd7d7 Don't Process Corner-Point Data If No Valid Cell Geometry
If no cell has a valid corner-point geometry, typically caused by
using GDFILE to read non-finite data such as all ZCORN = -1.0E+20,
then we must not attempt to generate a grid structure.  If we do, we
will typically just fail somewhere deep down in the corner-point
processing code and generate a diagnostic message that's hard to
decipher.

With this commit we instead output a diagnostic message of the form

    Failed to create valid EclipseState object.
    Exception caught: No active cell in input grid has valid/finite cell geometry
    Please check geometry keywords, especially if grid is imported through GDFILE

This may not be a lot better than the original diagnostic

    Processing grid
    flow: ${ROOT}/opm-grid/opm/grid/cpgpreprocess/preprocess.c:768: is_lefthanded: Assertion `! searching' failed.
    Aborted (core dumped)

but does at least suggest that the grid data may be faulty.
2022-03-25 14:35:55 +01:00
Bård Skaflestad
0cd2ce6589
Merge pull request #3824 from totto82/notswitchthp
Avoid switching to thp control if production is decreasing or injection is increasing
2022-03-25 14:34:30 +01:00
Tor Harald Sandve
f4d81e33f1 Avoid switching to thp control if it results in higher rates 2022-03-25 09:12:15 +01:00
Tor Harald Sandve
2d6794f077
Merge pull request #3849 from hakonhagland/glift_debug_rank
Cleanup gaslift debugging output code
2022-03-24 14:13:33 +01:00
Håkon Hægland
a3c131955f Omit one redundant debugging message 2022-03-24 13:47:57 +01:00
Håkon Hægland
fbd6c03dd6 Cleanup glift debugging output code 2022-03-24 12:42:46 +01:00
Tor Harald Sandve
32dfdc6198 improve initialization msw new wells 2022-03-24 09:53:46 +01:00
Markus Blatt
08fd5da6a7 Use empty string for buildtime if BUILD_TIMESTAMP is not set.
In combination with the relevant changes in opm-common this
prevent flow in binary Linux packages from having a timestamp in the
executable that changes with every rebuild.

With the changes in opm-common  one can now set the variable
OPM_BINARY_PACKAGE_VERSION to a meaningful version string (Debian
11.2: 2021.10-4). If that is done and flow is built from tarballs it
will now not have a time stamp and print the package version to the
PRT file. E.g.

Flow Version     =  2021.10 (Debian 11.2: 2021.10-1)
2022-03-23 22:46:40 +01:00
Tor Harald Sandve
519b5dd8cc
Merge pull request #3810 from totto82/refactor_bhpFromThpLimit_1
Refactor bhp from thp limit
2022-03-22 13:57:52 +01:00
Tor Harald Sandve
c067e5fafd
Merge pull request #3834 from totto82/avoid_closing
Handle case where bhp target is violated
2022-03-22 11:56:21 +01:00
Tor Harald Sandve
7d5a0a74eb Handle case where bhp target is violated 2022-03-21 09:52:41 +01:00