Commit Graph

8383 Commits

Author SHA1 Message Date
Bård Skaflestad
517db198f8 Report Guiderate Values in Strict SI Units
The output layer expects its input values to be strictly SI, but we
know that the GuideRate container's values are in output units.
2021-08-17 16:07:45 +02:00
Bård Skaflestad
6da47344a3 Record New Supported Keywords
We recently added support for

  * RPTONLY
  * RPTONLYO
  * SUMTHIN
2021-08-17 10:29:36 +02:00
Joakim Hove
581f571c9d Use SingleWellState for production and injection control 2021-08-15 09:07:39 +02:00
Joakim Hove
c381459804 Add Events member to SingleWellState 2021-08-15 09:03:14 +02:00
Joakim Hove
379e938ee1 Add status to SingleWellState 2021-08-15 09:03:14 +02:00
Joakim Hove
75eb65efb7 Use WellState::wells_ to infer well name 2021-08-15 09:01:21 +02:00
Joakim Hove
d5ab308fbd Add temperature to SingleWellState 2021-08-15 09:01:21 +02:00
Joakim Hove
1dd9b91ad3 Add member "bool producer" to SingleWellState 2021-08-15 09:01:21 +02:00
Joakim Hove
a54daf75e8 Add trivial class SingleWellState with bhp and thp 2021-08-15 09:01:21 +02:00
Arne Morten Kvarving
1ef981f35c use RAII for MPI initialization 2021-08-12 13:20:59 +02:00
Arne Morten Kvarving
d99f642dff add collective communication to generic vanguard 2021-08-12 12:08:43 +02:00
Tor Harald Sandve
ac4ee51a5f Merge pull request #3465 from totto82/updateWTS
Make sure potentials are computed in some corner cases
2021-08-10 14:15:22 +02:00
Tor Harald Sandve
a8fa2d74ef Merge pull request #3420 from totto82/removeDerivate
remove derivatives from well rate computations
2021-08-09 15:48:38 +02:00
Tor Harald Sandve
5cb81d36c9 re-compute potentials for pressure controlled wells with trivial rates 2021-08-09 13:41:50 +02:00
Tor Harald Sandve
cf61417b6d move update well test state to after potentials are calculated 2021-08-09 13:21:10 +02:00
Joakim Hove
2ac65d97d2 Merge pull request #3457 from akva2/janitoring
mark variables [[maybe_unused]]
2021-08-07 16:36:03 +02:00
Joakim Hove
f01cf74591 Merge two perforation data members in WellState 2021-08-04 16:48:18 +02:00
Tor Harald Sandve
153cd678c6 Add a derivative free version of the well rate calculations 2021-08-04 11:32:50 +02:00
Arne Morten Kvarving
08e950686f use .empty() instead of .size() comparisons 2021-08-04 09:19:03 +02:00
Arne Morten Kvarving
8d40860b0b mark variables [[maybe_unused]] 2021-08-04 08:44:03 +02:00
Joakim Hove
1cbc096d20 Merge pull request #3450 from joakim-hove/small
Small
2021-08-03 18:08:33 +02:00
Joakim Hove
d5f2b02716 Check production and injection constraints separately 2021-08-03 14:39:39 +02:00
Joakim Hove
6542a62cc0 Merge pull request #3452 from joakim-hove/constraint-bug
BUG? Make sure WellState injection control is updated
2021-08-03 14:38:20 +02:00
Joakim Hove
ea4cf8d28f Merge pull request #3428 from akva2/remove_altidx
remove ebos_altidx
2021-08-03 14:10:00 +02:00
Joakim Hove
c70f63b99b Make sure WellState injection control is updated 2021-08-03 13:54:59 +02:00
Tor Harald Sandve
43d129861f Merge pull request #3454 from plgbrts/gw1
adjustments needed for gas-water system
2021-08-03 12:01:34 +02:00
Kai Bao
5e74466aed Merge pull request #3445 from plgbrts/rateconvfixed
Rateconvfixed
2021-08-03 00:07:19 +02:00
Arne Morten Kvarving
78c5675daf changed: get rid of OPM_UNUSED macro usages
prefer anonymous parameters or c++17 [[maybe_unused]]
2021-08-02 14:55:41 +02:00
Paul Egberts
a80894d679 using if constexpr () 2021-08-02 13:39:55 +02:00
Paul Egberts
8e8f6c5ff2 fix compositionSwitchEnabled declaration. For gas-water it is disabled 2021-08-01 21:02:07 +02:00
Paul Egberts
70d43fbefc using has_wfrac(gfrac)_variable logic, In case of gas-water system GFrac is primary variable index 2021-08-01 20:51:28 +02:00
Paul Egberts
5be63a59e0 Introduction of has_wfrac(gfrac)_variables analogue to multisegmentwell implementation 2021-08-01 20:40:04 +02:00
Paul Egberts
367c762a06 moved WFrac, GFrac definition to StandardWellEval.hpp 2021-08-01 20:36:05 +02:00
Paul Egberts
d5653d9ca2 removed exit failure for gas-water system 2021-08-01 18:11:56 +02:00
Paul Egberts
e25b78f106 fix for relative change calculation for gas-water system 2021-08-01 18:09:54 +02:00
Paul Egberts
25393cddee removed throw for water-gas system 2021-08-01 17:57:08 +02:00
Joakim Hove
e01910adc2 Add methods WellState::size() and WellState::producer() 2021-07-26 14:21:50 +02:00
Joakim Hove
a39fcc9708 Set WellState::thp when loading restart file 2021-07-26 13:07:12 +02:00
Joakim Hove
057db0ec0e Add method WellState::name() 2021-07-26 13:07:12 +02:00
Paul Egberts
0efe03497a some clean up 2021-07-23 16:41:50 +02:00
Paul Egberts
92f7b19594 delete head message 2021-07-23 16:41:50 +02:00
Paul Egberts
a813d9e875 fix for the situation that hydrocarbon consist only of gas 2021-07-23 16:41:50 +02:00
Markus Blatt
ea4e4a1520 Merge pull request #3346 from Tongdongq/amgcl-support
Amgcl support
2021-07-21 15:02:25 +02:00
Bård Skaflestad
48e1af8bbe Address Static Code Analysis Warnings
In particular, don't print uninitialized memory (Reorder.cpp:left)
and don't capture objects ('prm') that aren't actually used.  While
here, refactor the initialization of the MT19937 random number
generator.  Constructing this object is too expensive to do for each
try, especially when we can just run the generator in place.
2021-07-13 11:37:57 +02:00
OPMUSER
272ae1c8f8 Minor updates
Delete time stamp
update WCONPROD, TRACER and TRACERS
2021-07-10 14:05:33 +08:00
OPMUSER
22a2720e5a Partially Supported Keywords Validation
All keywords that can be checked with the existing validation frame work. All failures will continue, even if the message says "will STOP". The only exception is GUIDERAT(2) as parser check results in the STOP; however, this going to change so the STOP will happen with this code.

Comments and agreement between continue and STOP actions appreciated-
2021-07-10 14:05:33 +08:00
OPMUSER
741fddc2f7 Update UnsupportedFlowKeywords with Some Output Comments
Just minor changes to the output strings for better clarity.
2021-07-10 14:05:33 +08:00
OPMUSER
82834c0a3b Unsupported Keywords: Fix RVCONST add ROCKOPTS
Added ROCKOPTS to unsupported keyword list, as there are no opm-test examples, is this correct?

If ROCKOPTS is supported what is supported?
2021-07-10 14:05:33 +08:00
Tong Dong Qiu
796d1b7f8a Allow to choose a platform and device when using amgcl with VexCL 2021-07-09 17:03:11 +02:00
Tong Dong Qiu
0ee6b58fb0 Only initialize VexCL once 2021-07-09 15:39:35 +02:00