Bård Skaflestad
2aac0d6cf5 Enable New Saturation Function Consistency Checks
The new parameter CheckSatfuncConsistency, command line option
--check-satfunc-consistency, allows users to opt into running the
checks.  The option currently defaults to 'false' to reflect the
somewhat experimental nature of the new facility.

The new parameter --num-satfunc-consistency-sample-points allows the
user to select the maximum number of reported failures for each
individual consistency check.  By default, the simulator will report
at most five failures for each check.

We check the unscaled curves if the run does not activate the
end-point scaling option and the scaled curves otherwise.  At
present we're limited to reversible and non-directional saturation
functions for the drainage process, but those restrictions will be
lifted in due time.
2024-10-16 15:03:07 +02:00
Bård Skaflestad
b5305b928d Use More Specific Name for 'anyFailedChecks'
The function returns whether or not there were any failed checks at
the 'Standard' level.  Make the function name reflect this.
2024-10-16 09:32:19 +02:00
Bård Skaflestad
8082e72d32 Add Top Level Container for Saturation Function Consistency Checks
This commit introduces a new top-level "manager" for all saturation
function consistency checks.  This component associates collections
of saturation function curves with per-cell or per-region end-point
definitions and provides an interface to run all checks for all
interior entities (i.e., active cells) in a DUNE grid view.  We form
one set of SatfuncConsistencyChecks objects for each
SatfuncCheckPointInterface<> object, thereby enabling running the
same set of consistency checks for both the unscaled, tabulated,
per-region saturation functions and the per-cell scaled saturation
functions.  The latter is executed only if the run enables end-point
scaling for the saturation functions while the former is executed
only if the run does not enable end-point scaling.

At present we're limited to reversible and non-directional
saturation functions for the drainage process only, but those
restrictions will be lifted in due time.

As an aid to enabling the pertinent individual checks, we add a
private factory function which considers the run's active phases and
whether or not the run uses the alternative, three-point horizontal
scaling method ("SCALECRS = YES").
2024-10-16 09:32:19 +02:00