opm-simulators/restartTests.cmake
Bård Skaflestad f156bc9b7d Enable Restart Tests for Constant Flux Aquifers
Uses the example models AQUFLUX-01 and AQUFLUX-02 from OPM-Tests.
Both sequential and parallel modes activated for both models.
2023-05-26 20:21:52 +02:00

120 lines
6.1 KiB
CMake

# Restart tests
opm_set_test_driver(${PROJECT_SOURCE_DIR}/tests/run-restart-regressionTest.sh "")
# Cruder tolerances for the restarted tests
set(abs_tol_restart 2e-1)
set(rel_tol_restart 4e-4)
add_test_compare_restarted_simulation(CASENAME spe1
FILENAME SPE1CASE2_ACTNUM
SIMULATOR flow
ABS_TOL ${abs_tol_restart}
REL_TOL ${rel_tol_restart}
RESTART_STEP 6
TEST_ARGS --sched-restart=false)
add_test_compare_restarted_simulation(CASENAME spe9
FILENAME SPE9_CP_SHORT
SIMULATOR flow
ABS_TOL ${abs_tol_restart}
REL_TOL ${rel_tol_restart}
RESTART_STEP 15
TEST_ARGS --sched-restart=false --tolerance-mb=1e-7)
add_test_compare_restarted_simulation(CASENAME ctaquifer_2d_oilwater
FILENAME 2D_OW_CTAQUIFER
SIMULATOR flow
ABS_TOL ${abs_tol_restart}
REL_TOL ${rel_tol_restart}
DIR aquifer-oilwater
RESTART_STEP 15
TEST_ARGS --sched-restart=true)
add_test_compare_restarted_simulation(CASENAME fetkovich_2d
FILENAME 2D_FETKOVICHAQUIFER
SIMULATOR flow
ABS_TOL ${abs_tol_restart}
REL_TOL ${rel_tol_restart}
RESTART_STEP 30
DIR aquifer-fetkovich
TEST_ARGS --sched-restart=true)
add_test_compare_restarted_simulation(CASENAME numerical_aquifer_3d_1aqu
FILENAME 3D_1AQU_3CELLS
SIMULATOR flow
ABS_TOL 0.4
REL_TOL 4.0e-3
RESTART_STEP 3
DIR aquifer-num
TEST_ARGS --sched-restart=true --enable-tuning=true)
add_test_compare_restarted_simulation(CASENAME numerical_aquifer_3d_2aqu
FILENAME 3D_2AQU_NUM
SIMULATOR flow
ABS_TOL 0.4
REL_TOL 4.0e-3
RESTART_STEP 3
DIR aquifer-num
TEST_ARGS --sched-restart=true --enable-tuning=true)
add_test_compare_restarted_simulation(CASENAME aquflux_01
FILENAME AQUFLUX-01
SIMULATOR flow
ABS_TOL ${abs_tol_restart}
REL_TOL 3.0e-3
RESTART_STEP 3
DIR aquifers
TEST_ARGS --enable-tuning=true)
add_test_compare_restarted_simulation(CASENAME aquflux_02
FILENAME AQUFLUX-02
SIMULATOR flow
ABS_TOL ${abs_tol_restart}
REL_TOL ${rel_tol_restart}
RESTART_STEP 50
DIR aquifers
TEST_ARGS --enable-tuning=true)
# The dynamic MSW data is not written to /read from the restart file
# We therefore accept significant deviation in the results.
# Note also that we use --sched-restart=true since some necessary
# MSW info is still lacking in the restart file.
set(abs_tol_restart_msw 2e2)
set(rel_tol_restart_msw 1e-3)
add_test_compare_restarted_simulation(CASENAME msw_3d_hfa
FILENAME 3D_MSW
SIMULATOR flow
ABS_TOL ${abs_tol_restart_msw}
REL_TOL ${rel_tol_restart_msw}
RESTART_STEP 10
TEST_ARGS --enable-adaptive-time-stepping=false --sched-restart=true --tolerance-wells=1e-7)
# Basic restart tests which only compare the summary output, this test driver should
# only be used in situations where it is challenging to get agreement in the restart file.
opm_set_test_driver(${PROJECT_SOURCE_DIR}/tests/run-summary-restart-regressionTest.sh "")
add_test_compare_restarted_simulation(CASENAME spe1_actnum
FILENAME SPE1CASE2_ACTNUM
SIMULATOR flow
TEST_NAME restart_spe1_summary
ABS_TOL ${abs_tol_restart}
REL_TOL ${rel_tol_restart}
RESTART_STEP 6
TEST_ARGS --sched-restart=false
DIR spe1)
# Serialized restart tests
if(HDF5_FOUND)
opm_set_test_driver(${PROJECT_SOURCE_DIR}/tests/run-serialization-regressionTest.sh "")
add_test_compare_restarted_simulation(CASENAME spe1_serialized
DIR spe1
FILENAME SPE1CASE1
SIMULATOR flow
TEST_NAME compareSerializedSim_flow+spe1
ABS_TOL 2e-2
REL_TOL 1e-5
RESTART_STEP 94
TEST_ARGS --tolerance-mb=1e-7)
endif()