we do the compostional related in GenericOutputBlackoilModule to minimize the code change.
there needs to be refatoring for GenericOutputBlackoilModule to split
the black oil and compostional related.
currently, it looks the value for ZMF is based on XMF and YMF.
ideally, the ZMF is part of the primary varialbes, it does not need to
be calculated based on XMF and YMF.
there is some refactoring that we can do here.
so the FlowProblemComp can output ecl style output.
it duplicates the OutputBlackoilModule and GenericOutputBlackoilModule
for compositional related output for now.
This commit switches to using the 'welpi_wells' information from the
SimulatorUpdate structure as a basis to decide the wells for which
it is safe/sufficient to update only the CTFs in response to an
ACTIONX block running WELPI. To this end, we split the actions of
the existing member function updateEclWells() into two parts,
1. updateEclWellsConstraints()
2. updateEclWellsCTFFromAction()
in which the first handles well status and well control updates
while the second deals with CTF updates in response to WELPI. We do
not run the second part if the well structure has changed--e.g., due
to COMPDAT or WELOPEN--since the update loop depends on a static
connection topology.
We add a new member function wellUpdateLoop() which will traverse a
sequence of well names and invoke a loop body on those wells which
exist in wells_ecl_. This collects common operations needed for
both the constraints and the CTF updates.
The new parameter CheckSatfuncConsistency, command line option
--check-satfunc-consistency, allows users to opt into running the
checks. The option currently defaults to 'false' to reflect the
somewhat experimental nature of the new facility.
The new parameter --num-satfunc-consistency-sample-points allows the
user to select the maximum number of reported failures for each
individual consistency check. By default, the simulator will report
at most five failures for each check.
We check the unscaled curves if the run does not activate the
end-point scaling option and the scaled curves otherwise. At
present we're limited to reversible and non-directional saturation
functions for the drainage process, but those restrictions will be
lifted in due time.